:: 3 PHASE IN 1 OUT UPS (8310 Series) ::
 
  • 100% digital technology
    Self-diagnosis, circuit control, parameters setting and program management are based on 3 high speed micro-controllers.
  • Applies high-tech components
    DDC (Direct Digital Control),DSP(Digital Signal Processing),ASIC (Application Specific IC) and CPU are used in this system.
  • Super performance from IGBT
    High speed on/off,operating on high voltage and large current,simple gate control circuits(voltage-controlled),high efficiency and high stability.
  • Fully meets sharp load fluctuation from 0 to 100%
    Completely meet the requirements of sharp load fluctuation without transferring to bypass and maintain the output within tolerance.
  • Large screen LCD display
    Users can conveniently operate the UPS accordingly to the instructions and easily get UPS operating status at any time via large screen LCD.
  • Perfect protections
    Built-in over/low-voltage,over-current,overload and short circuit protections ensure lowest failure rate.
  • Low output voltage distortion
    Owing to pratial circulating current control, inverter could rapidly control impulse current from load change and surge.UPS can quickly respond to load change via feedbak control.
  • Intelligent battery management
    UPS will automatically charge and discharge the battery in float charging or boost charging mode to the cycle set by the internal software, and automatically maintain the battery without manual operation,which prolongs the battery life.

 

 

 


Technical Specification
(8310 Series)

 
 
Technical Specifications - 8310 Series

Model No.  UPS Rating
                  / Capacity
OSOL10000 OSOL15000 OSOL20000 OSOL30000
10 KVA 15 KVA 20 KVA 30 KVA
8 KW 12 KW 16 KW 24 KW
Operating Mode & Principle True On-Line, Double Conversion, Input & Output Galvanic Isolation
Technology PWM / IGBT
INPUT
Phase 3 Phase + N + G
Voltage 380V + 25%
Frequency 50 Hz + 5Hz
P. F. 0.92 P.F.
Bypass Input
Phase 3 Phase + N + G
Voltage 380 V + 25%
Frequency  50 Hz + 5Hz
Transfer Time 0ms. Inverter to Bypass (Over Load)
DC System
DC Voltage 360 V DC
Charging Current 1Amp – 30Amp (Adjustable)
OUTPUT
Phase Single Phase
Voltage 230V + 1%
Frequency  50 Hz + 0.5Hz
Waveform Pure Sine Wave
P. F. 0.8
Distortion  < 3% (On-Liner Load), < 5% (On Non-Liner Load)
Transient < 10ms.
Over Load 125% for 1 Min.
  150% for 1second
Cooling Forced Air Cooled
PROTECTION
General Output Over Load, Short Circuit, Over Temp., Battery Low & Over Charge
Audible Alarm Mains Fail, Load On Battery, Inverter Fault
SYSTEM
Over All Efficiency 91% 92%
Communication RS-232 Port OR SNMP (Optional)
Temperature 0O C To 40O C
Humidity 30 To 90%
Noise (db) 40 – 60 db
 